Gilderfluke&Co Frequency Shift Keyed/Remote Terminal Unit User Manual
Page 10

are what are called ‘insulation displacement connectors’. These simply snap on to an entire
cable, automatically ‘displacing’ the wire insulation and making contact with the wires within.
This means that an entire 40 wire cable can be terminated in seconds. All connectors are po-
larized, to keep them from being plugged in backwards.
Each J6/A cable is arranged in the following order:
wire number
color
wire function
1
brown
circuit ground
2
red
+ unregulated power supply (protected to 1 amp)
3
orange
Output 15 (0Fh) Positive Analog Output
4
yellow
Output 15 (0Fh) Negative Reference
5
green
Output 14 (0Eh) Positive Analog Output
6
blue
Output 14 (0Eh) Negative Reference
7
violet
Output 13 (0Dh) Positive Analog Output
8
gray
Output 13 (0Dh) Negative Reference
9
white
Output 12 (0Ch) Positive Analog Output
10
black
Output 12 (0Ch) Negative Reference
11
brown
circuit ground
12
red
+ unregulated power supply (protected to 1 amp)
13
orange
Output 11 (0Bh) Positive Analog Output
14
yellow
Output 11 (0Bh) Negative Reference
15
green
Output 10 (0Ah) Positive Analog Output
16
blue
Output 10 (0Ah) Negative Reference
17
violet
Output 9 (09h) Positive Analog Output
18
gray
Output 9 (09h) Negative Reference
19
white
Output 8 (08h) Positive Analog Output
20
black
Output 8 (08h) Negative Reference
21
brown
circuit ground
22
red
+ unregulated power supply (protected to 1 amp)
23
orange
Output 7 (07h) Positive Analog Output
24
yellow
Output 7 (07h) Negative Reference
25
green
Output 6 (06h) Positive Analog Output
26
blue
Output 6 (06h) Negative Reference
27
violet
Output 5 (05h) Positive Analog Output
28
gray
Output 5 (05h) Negative Reference
29
white
Output 4 (04h) Positive Analog Output
30
black
Output 4 (04h) Negative Reference
31
brown
circuit ground
32
red
+ unregulated power supply (protected to 1 amp)
33
orange
Output 3 (03h) Positive Analog Output
34
yellow
Output 3 (03h) Negative Reference
35
green
Output 2 (02h) Positive Analog Output
36
blue
Output 2 (02h) Negative Reference
37
violet
Output 1 (01h) Positive Analog Output
38
gray
Output 1 (01h) Negative Reference
39
white
Output 0 (00h) Positive Analog Output
40
black
Output 0 (00h) Negative Reference
Analog loads are connected between each of the Positive outputs and its associated
Negative reference. The output capacity of each output is 20 ma. The output voltage range
can be adjusted from the FSK/RTU to anywhere between 0 and 10 volts. Current amplifiers are
available if additional current capacity is required for your application.
The negative reference is at a voltage of approximately 1.6 volts above the circuit ground.
The negative references are all connected on the FSK/RTU, but there must be no direct con-
nections made between any of the negative references and the circuit grounds anywhere
in the animation system.