beautypg.com

Setting up the sampling train without a cyclone – SKC 225-317 SKC Diesel Particulate Matter (DPM) FIlter Cassette User Manual

Page 2

background image

Setting Up the Sampling Train with Cyclone and Holder

1. Insert stem of GS-1 Cyclone into large hole in cassett e holder.

2. Orient cyclone in holder until the small round nodule on the bowl adapter

rim fi ts into the notch in the cassett e holder.

3. Remove inlet and outlet plugs from a DPM Cassett e, pull back spring-loaded

hold-down plate on cassett e holder, and gently push inlet of cassett e onto
top of cyclone.

4. Position small hole in hold-down plate over cassett e

outlet.

5. Insert Luer adapter on the holder's rubber tubing into

cassett e outlet.

Figure 2. DPM Sampling Train with GS-1 Cyclone,

Cassette Holder, and Universal PCXR4 Pump

Setting Up the Sampling Train without a Cyclone

1. Remove the plug from the outlet of the cassett e (Figure 1).

2. Att ach one end of a length of Tygon

®

tubing to the cassett e outlet and the

other end to the inlet of an air sample pump capable of maintaining the
desired fl ow rate.

3. Secure the cassett e on a worker by using a cable tie and collar clip.

4. Remove plug from the cassett e inlet immediately before sampling.

AIRCHEK

SAMPLER

SAMPLE PERIOD — MINUTES

START

HOLD

FLOW

AND

BATTERY

CHECK

FLOW

ADJ

ON

5

4

3

2

1

AIRCHEK SAMPLER

MODEL 224-PCXR8

UL

®

LISTED 124U

SERIAL NO.
SKC INC.
EIGHTY FOUR PA 15330

WARNING - SUBSTITUTION OF
COMPONENTS MAY IMPAIR INTRIN
SIC SAFETY. USE ONLY UL LISTED
PORTABLE AIR SAMPLING PUMP
BATTERY PACK MODEL P21661

INTRINSICALLY SAFE

PORTABLE AIR SAMPLING PUMP
FOR USE IN HAZARDOUS LOCA
TIONS CLASS I, GROUPS A B C D
AND CLASS II, GROUPS E F G
AND CLASS III, TEMPERATURE
CODE T3C.