SKC 226-120 Sorbent Sample Tube User Manual
Operating instructions, Certifi cate of quality, Description
Sorbent Sample Tube
Cat. No. 226-120
Description
Sorbent sample tube Cat. No. 226-120 is a three-section tube containing 300 and
150 mg of DNPH-coated silica gel, respectively (sample section and backup section
to detect breakthrough), and a 1500 mg section of potassium iodide that acts as an
ozone scrubber.
Sampling
The 226-120 sorbent sample tube can be used at fl ow rates up to 1 L/min. For
additional sampling parameters, consult the method used. Sampling parameters
may vary with ambient concentrations of the analyte.
This sorbent tube is not recommended for the collection of acrolein due to
numerous problems reported with the instability of the acrolein-DNPH derivative
during collection and storage.
Sampling Notes
Ozone: Ozone interference is associated with DNPH-coated adsorbent tubes.
Sorbent sample tube Cat. No. 226-120 contains a built-in ozone scrubber that may
be used in atmospheres where ozone is present to help eliminate this interference.
Acetonitrile: The sorbent inside these tubes contains a small amount of residual
acetonitrile used in processing the sorbent. Acetonitrile may off-gas during
sampling; therefore, exposure monitoring for acetonitrile should not be performed
concurrently when these sorbent tubes are in use.
Background
See Certifi cates of
scrolling to Silica Gel, DNPH T
matches the Lot Number printed on the tube.
Preparing Formaldehyde Samples for Analysis
1. Place each sorbent section into separate glass vials. Discard the ozone scrubber
section according to state and federal guidelines.
2. Add 3 ml of acetonitrile to each vial. Cap each vial.
3. Shake each vial periodically over a 30-minute period.
4. Analyze sample extracts by HPLC with UV detection at 365 nm.
Operating Instructions
863 Valley View Road, Eighty Four, PA 15330 USA
Tel: 724-941-9701 Fax: 724-941-1369 e-mail: [email protected]
Cat. No. 226-120
Form 37356 Rev 1305
Sorbent:
Silica Gel coated with
2,4-Dinitrophenylhydrazine
with
potassium iodide ozone scrubber
Tube Holder: Type D
Storage: Store
at
≤ 39.2 F (4 C) before use.
After sampling, store at ≤ 39.2 F (4 C).
Expedite shipping of samples to the laboratory.
Friday shipments are not recommended.
Certifi cate of Quality
SKC is an ISO 9001 registered
manufacturing company.
For compliance sampling, use these tubes as specifi ed in a validated sampling method. It is the user’s
responsibility, employing a suitable method, to establish appropriate safety and health practices and
to determine the applicability of regulatory limitations before use. The user should adjust the sampling
procedures to specifi c conditions and should test tubes to ensure that the desired results will be obtained.
The SKC Certifi cate of Quality assures that these sorbent tubes have been manufactured to meet or
exceed the requirements for sorbent purity, sample collection and retention, storage stability, and
desorption effi ciency for the following chemical hazards and analytical methods published by NIOSH,
OSHA, EPA, or ASTM:
Acetone ASTM
D5197
Aldehydes ASTM
D5197
Formaldehyde ASTM
D5197
Formaldehyde EPA
IP-6A
Formaldehyde EPA
TO-11A
Hexanaldehyde (hexanal)
ASTM
D5197
SKC Limited Warranty and Return Policy