AccuPower AQU244B
Installation Instructions
Recommended Tools & Additional Materials
#2 Phillips Screw Driver
Wire connectors
Lead Acid or Gel Cell Batteries*
1/16” Flat head Screw Driver
6-32x1/4” Mounting screws (QTY4)
*See Battery sizing guide on page 6.
AccuPower AQU244B Specifications
Mechanical
Electrical
Environmental
Regulatory
Physical Size:
Board: 3 15/16” x 7 3/8” x 2 3/8”
Mounting: : 3 1/2” x 6 13/16”
Weight*
AQU244B
1.5 lbs
Input Voltage Operating
Range
110-240VAC
47-63Hz
Maximum Output Voltage
120 VA
5 Amps @ 24VDC
Continuous Output Voltage:
96A
4 Amps @ 24VDC
Voltage Range:
18.5 - 28 VDC/ 27.3V typical
Frequency
23 KHz
Operating
Temperature
0ºF to 130ºF
[-17 to 54ºC]
Humidity
10% to 95% RH
For Indoor use
Recognized
Component:
UL294 Listed
UL603 Listed
cUL Listed
RoHS Compliant