What to do if the ADMIN password has been forgotten

If the ADMIN password becomes mislaid or forgotten, you will not be able to
access the AdderView CATx 1000 to add or edit users and computer names.
This situation may be resolved by performing a complete reset to return the
AdderView CATx 1000.
IMPORTANT: A complete reset erases all the user names and computer
names that you have setup.

To clear a password (and restore factory default settings)

1 Remove power from the AdderView CATx 1000 unit.
2 Connect the AdderView CATx 1000 unit to a computer in the same

manner as you would to carry out a flash upgrade - see

Performing flash

upgrades

.

3 Press and hold the reset button on the front panel (requires paper clip or

similar).

4 Apply power and after 3 seconds release the reset button. The ‘UPG’ LED

should now be iluminated.

5 Set the computer serial settings to the following: 19200, n, 8, 1
6 Using ‘TeraTerm’ (recommended) or an alternative terminal program, send

“CLEAR” - in upper or lower case from the keyboard. The AdderView
CATx 1000 unit should respond with “OK”.

7 The password is now clear and all factory default settings restored.