Remote switching control, Remote switching, Control – Adder Technology AdderView CATx 1000 User Manual
Page 18

5V
2.0A
12
1
16
1
OPTIONS
COMPU
T
Remote switching control
The port switching functions of the AdderView CATx 1000 
units can be remotely controlled by an RS232 link to the 
OPTIONS
port on the rear panel.
The sending device must use the following RS232 
communication settings: 
Baud rate: 19200 bps 
Data bits: 
8
Parity:
None
Stop bits:
1
No handshaking is implemented, however, valid command characters will be 
echoed back to the sending device.
The value of the byte received via the serial link determines which computer port 
should be linked through to the user port. The table given here summarises the 
valid control codes: 
REMOTE
CONTROL
0
0
10
11
12
13
14
15
16
17
18
19
1A
1B
1C 1D
1E
1F
71
Host computer port/channel
(video off)
Cable from serial
control device
AdderView CATx 000