Remote user (via X100/X200 extender)

One user can be placed a maximum of 300
metres (980 feet) from the AdderView CATx
1000 unit. The remote user is connected via
an Adder X100 or X200 extender module and
suitable category 5, 5e or 6 cabling (with no
crossover).
Note: It is not possible to connect a remote
user while the unit is cascaded to another unit.

REMOTE

USER

Overall maximum length between the remote user and

any host system must not exceed 300 metres (980 feet)

300 metres (980 feet)

maximum

10 metres

(32 feet)

maximum

X100

CAM COMPUTER

SYSTEM

In situations where any computer system will be placed a significant distance
from the AdderView CATx 1000 unit, ensure that the distance to any remote
user is similarly less than 300 metres (980 feet).
To connect a remote user

1 Place an Adder X100 or X200 extender unit adjacent to the remote user

location.

2 Attach the video monitor,

keyboard, mouse, power adapter
(and speaker) connectors to the
sockets of the Adder
X100 or X200
module.

3 Lay a suitable length of category 5, 5e or 6 cabling between the Adder

X100/X200 module and the AdderView CATx 1000 unit. Please refer to the
section Cable lengths for remote user locations opposite.

4 Attach the connector of the cable run to the socket of the Adder X100/X200.

5 At the other end of the cable run, attach the cable connector to the socket

on the front panel of the AdderView CATx 1000 unit.

From mouse

From keyboard

From video monitor

From power adapter

Category , e or

cable leading to

AdderView CATx 000

unit

Category , e or cable

from Adder X00/X00

module

6 Where necessary, use the in-built video compensation feature of the Adder

X100/X200 module to eliminate any effects caused by the cable run.

Adder X00

module

Adder X00/X00

module

AdderView CATx 000

front panel

LOCAL

USER

REMOTE

USER

X200

POWER

IN

POWER

SWITCH

COMPUTER

SYSTEM

CAM

KVM

only

Cable lengths for remote user locations
The maximum length of cable between the remote user and the AdderView
CATx 1000 unit can be up to 300 metres (980 feet). However, bear in mind that
the overall distance between the remote user and any computer system must
not exceed 300 metres (980 feet).