Securing an mvp panel to an mvp-wds – AMX Wall Docking Station MVP-WDS User Manual
Page 22
![background image](/manuals/34887/22/background.png)
MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box
16
MVP-WDS Wall Docking Station for MVP Panels
Securing an MVP Panel to an MVP-WDS
1.
Place the MVP-WDS on a flat and level surface.
2.
Provide power to the MVP-WDS (refer to the Powering the MVP-WDS section on page 14).
3.
Place the MVP on the support cradle so that the alignment pins on the WDS fit into the matching
holes on the bottom of the MVP.
4.
Once proper alignment is verified, gently angle back the MVP until the rear of the panel makes
contact with the electromagnet. Allow one second to activate the electromagnet.
When the MVP is properly docked, the following message is displayed on the panel (FIG. 18).
Proper docking and communication can be verified via the on-screen system message, or the
illuminated Docking Status button on the Protect Setup page, or the right LED on the docking
station.
FIG. 16
MVP-TDS Connector Pin locations and Pinout function
FIG. 17
Installing an MVP onto an MVP-WDS
2
1
18
17
1 - Data - Panel Detect IN
2 - Ground
3 - not used
4 - Ground
5 - not used
6 - Ground
7 - not used
8 - not used
9 - not used
10 - DC Power
11 - Data - Receive
12 - DC Power
13 - Data - Transmit
14 - DC Power
15 - Data - USB Device D-
16 - Data - Cradle Detect
17 - Data - USB Device D+
18 - Data - Panel Detect OUT
Alignment
guide pins
Connector
pins