9060 Cascade Low Voltage Controller - Operation

CP-13-07.2

26

Voltage Cable Fault (UC)

This fault will occur if the microprocessor de-
tects a loss of the voltage feedback signal.
This may indicate a failed pc board. See Fault
Troubleshooting Section for more information.

Figure 27: Voltage Cable Fault Display

Feedback Fault (FF)

This fault will occur if the microprocessor de-
tects a loss of the current feedback signal. If
this occurs, reset the fault. If this fault occurs
repeatedly, replace the handgun barrel or the
pc board.

Figure 29: Feedback Fault Display

Over Voltage Fault (OU)

This fault will occur if the microprocessor de-
tects the unit is trying to output voltage above
the required for the specific applicator type. If
this occurs, reset the Controller. If this fault
continues to occur, replace the main PC
board.

Figure 28: Over Voltage Fault Display

Boot Fault (bF)

This fault will occur during the start-up se-
quence if an active trigger signal is present. It
is designed to prevent immediate triggering
after start-up as the unit should be allowed to
enter the “ready” state prior to being triggered.
This fault also prevents the high voltage from
being fired if the microprocessor resets. For
additional information, refer to the Fault Trou-
bleshooting Section.

Figure 30: Boot Fault Display