beautypg.com

General Tools and Instruments RGR150 User Manual

Page 10

background image

• Press and hold the back panel ALARM

button for two seconds. The “30” number
will flash, meaning that if selected, the
alarm will sound 30 minutes earlier than
the Weekday or Single alarm.

• Enter the desired minutes from 15 to

90 minutes in 15 minutes intervals, using
UP () or DOWN ().

• Press back panel ALARM button again to

confirm and exit from the alarm setting
mode.

ACTIVATING THE ALARM

• Press ALARM ON/OFF button to enter into

the alarms mode.

• Press DOWN () to activate or UP () to

deactivate desired alarm. When alarms
are activated, the corresponding icons
will be displayed.

SNOOZE
When any alarm sounds, press the
SNOOZE/LIGHT button to temporarily stop the
alarm. After the SNOOZE/LIGHT is depressed,
the alarm sound will resume in eight minutes.
If the alarm is not disabled after that, it will
sound for four more minutes and then will
stop by itself.

PRECAUTIONS
This product is engineered to give you years of
satisfactory service if handled carefully. Here
are a few precautions:

• Do not immerse the units in water.
• Do not clean the units with abrasive or

corrosive materials. They may scratch the
plastic parts and corrode the electronic
circuits.

• Do not subject the product to excessive

force, shock, dust, temperature, or
humidity, which may result in
malfunctions, shorter lifespan, damaged
batteries, and damaged parts.

• Do not tamper with the units internal

components. Doing so will invalidate the
warranty and may cause damage. These
units contain no user-serviceable parts.

• Use only fresh batteries. Do not mix new

and old batteries.

• Read the user’s manual thoroughly before

operating the units.

SPECIFICATIONS

Main Unit
TIME
12/24 hour display in hh: mm format
Date format: month-day or day-month format
Day of the week is selectable in five languages
(English, Spanish, French, German, Italian)
Time zone manual adjustment
Dual two-minute crescendo alarms with
8 minutes snooze
Programmable ice warning alarm (Channel 1)

WEATHER
Rainfall
Proposed operating range:

0 to 1999.9mm/0 to 78.74 inch

Rainfall resolution: 0.04 inch (1mm)
Indoor Temperature
Proposed operating range:

23.0º to 122.0ºF (-5.0º to +50.0ºC)

Temperature resolution: 0.2ºF (0.1ºC)
User-selectable (ºF or ºC) temperature display
LED backlight
Low battery indicator
Wall Mount or Desktop option

REMOTE RAIN GAUGE
Remote Rainfall Data
Proposed operating range:

23.0º to 122.0ºF (-5.0º to 50.0ºC)

RF transmission frequency: 433 MHz
RF transmission range:

maximum 100 feet (30 meters)

Rainfall transmission cycle: approximately
183 seconds

RGR150 manual-FINAL-091908:Layout 1 9/19/08 8:59 AM Page 10