background image

GENERAL PUMP

A member of the Interpump Group

LK SERIES

Unscrew the connecting rod screws (pos.1, fig. 17).

Dismantle the small ends of the connecting rods with the half-bearings. During the operation take particular

care to note the order in which the parts are removed

The connecting rod small ends and the big end halves must be reassembled in exactly the

same order and pairings in which they were dismantled.

To prevent any errors, small ends and big end halves are numbered on one side (pos. 1, fig. 18).

Advance the three big end halves as far as possible in the direction of the head. Slip off the three upper half-

bearings of the beg end halves (pos. 1, fig 19).

Page 8