beautypg.com

He series, General pump – General Pump HE User Manual

Page 14

background image

GENERAL PUMP

A member of the Interpump Group

HE SERIES

Page 14

Bolt torquing is to be carried out by

means of a torque wrench only:

12. TORQUE SPECIFICATIONS

13. MAINTENANCE TOOLS

The following tools are designed to

facilitate mounting and dismounting

operations of some pump components:

for disassembling:

-cylinder extractor

F200000200

-piston guide

F200000140

oil seal extractor

For assembling:

- Piston guide oil seal

F200000030

14. PUMP STOPPED FOR LONG TIME

Before starting the pump for the very first

time after a long period from the date of

shipment check for the correct oil level,

check the valves as indicated in chapter

11 and then comply with the starting

procedures indicated in chapter 10. When

a long inactivity is scheduled drain the

entire suction and delivery line and then

run the pump dry only for a few seconds

in order to drain out the water collected

inside the fluid end.

15. PRECAUTIONS AGAINST FREEZING

In the risk of freezing the following

precautions should be taken:

-

after use drain the entire suction and delivery lines

(filter included) by means of discharging devices,

provided and positioned specifically for this purpose

along the lowest point of the lines.

-

run the pump only for a few seconds in order to

drain the water collected inside the fluid end.

Or when applicable

-

add a recommended amount of anti-freeze into the

water tank and run the pump until the anti-freeze

works all through the system.

If a pump is frozen or appears frozen ON NO ACCOUNT

SHOULD THE PUMP BE OPERATED until the entire

system has been thawed out.

DESCRIPTION

Ft. Lbs.

N-m

Kgm.

Head Bolts

144.6

196

20

Plunger bolts

18

24.5

2.5

Connecting Rod

Screws

28.9

39.2

4