In order to replace the pressure packings (3, Fig. 16)

loosen and remove the packing support (1, Fig 16) from

the cylinder (2, Fig 16.)

Remove the scraper (1, Fig. 17) and relevant o-ring

(2, Fig. 17) from the packing support. Pressure packings

and o-rings should always be replaced at every

disassembling of the pump.

In order to fit the scraper in place, shape it manually as

shown in Fig. 18.

VERY IMPORTANT! The scraper is provided with an

internal lip which performs the correct scraping effect

only if oriented towards the fluid end. See window

inside Fig. 18.

Before reassembling the pump unit carefully clean the

pressure packing seat in the packing supports, fit in place

the packing ring (1, Fig. 19) and then the pressure

packings (2, Fig. 19). A little bit of grease helps when

sliding the packings into the packing support.