Section 3 - Maintenance

The FMBC-2000 Series was engineered for low maintenance; however, some conditions will cause increased wear on the paddle and/or possible
damage to the unit. Damage caused by corrosives incompatible with the meters materials of construction or abrasive fluids is not covered under
warranty.

• Periodically remove the sensor from the molded in-line body and inspect for signs of wear and obstructions. Clean the paddle of any foreign

material. Inspect the o-rings for any sign of wear, swelling, cracking or discoloration. Replace if necessary.

• The meter is designed to withstand minor condensation inside the enclosure. Prolonged excessive moisture inside the enclosure, due to high

humidity conditions, may damage the meter. Reduce the humidity or move the meter to a cool, dry location.

7

Figure 2 - Factory Default Chart