Maximum performance limits, Technical data, S6 sample label – Finish Thompson S6 User Manual
Page 11
11
Motor Specifications
Rechargeable Motor (2 speed)
Specifications
Model S6
Battery Voltage
12 volts* (10.8 volts)
Battery Capacity/Type
3,200 mAh/Lithium Ion
Input/Output Power
150/100 Watts
Duty Cycle
Continuous
RPM (low/high speed)
8,000/12,000
Maximum Flow
14 gpm(53 lpm) @ high speed
8 gpm (30 lpm) @ low speed
Maximum Head
13 ft (4 m) @ high speed
7 ft (2 m) @ low speed
Maximum Viscosity
100 cP @ high speed
25 cP @ low speed
Maximum Specific Gravity
1.2 @ high speed
1.6 @ low speed
Approximate Run Time
Between Charges
20 minutes @ high speed
50 minutes @ low speed
Maximum Fluid Pumped
on Full Charge
275 gal (1,703 l) @ high speed
450 gal (1,040 l) @ low speed
Enclosure
Splashproof, IP24
Certifications/Approvals
CE
*Maximum initial voltage is 12 volts. Under workload, nominal voltage is 10.8.
Maximum Performance Limits
High Speed
Motor Setting
If specific
gravity is:
viscosity can
not exceed:
Max. Flow
gpm (lpm)
Max. Head
ft (m)
1.0
100 cP
3 (11.4)
14 (4.3)
1.1
50 cP
7 (26.5)
11(3.4)
1.2
1 cP
12 (45.4)
9 (2.7)
Low Speed
Motor Setting
If specific
gravity is:
viscosity can
not exceed:
Max. Flow
gpm (lpm)
Max. Head
ft (m)
up to 1.6
25 cP
6 (22.7)
3 (0.9)
Technical Data
0
2
4
6
8
10
12
14
0
2
4
6
8
10
12
14
16
H
ea
d
-ft.
(m
ete
rs
)
Flow - gpm (lpm)
Performance (on water)
Full Speed
Low Speed
S6 Sample Label
MODEL:
PART NO:
SERIAL NO:
921 Greengarden Road * Erie, PA 16501-1591 U.S.A.
Ph 814-455-4478 * Fax 814-455-8518
FINISH THOMPSON, INC.
10.8V
Date of Mfg:
WARNING!
THIS EQUIPMENT
IS NOT EXPLOSION PROOF
DO NOT use this equipment in or near
flammable or combustible liquids!
DO NOT submerge this motor in fluid!
DO
read proper operation and safety
precautions in instruction manual.
CAUTION: Do not expose to
temperatures above 104°F (40°C.)
DO wear eye and skin protection
S6
107951
10/27/12
ONLY charge w/ F.T.I. Li-Ion Charger
IP24
97182 J12
35 Wh
3200 mAh