beautypg.com

Head and vapor seal change - pfm, pfp, pfv series, Vapor seal, Impeller housing change - pfm, pfp, pfv series – Finish Thompson PFV User Manual

Page 10: Head

background image

8

Head and Vapor Seal Change - PFM, PFP, PFV Series

In October 2010, Finish Thompson made a change to the head

(item 5) and the seal (item 4) on the plastic PF Series pumps.

Make sure the correct parts are ordered when repairing a pump

Should you have a question about this change, please
contact our Technical Service Department at 800-888-3743.

Vapor Seal

The primary part affected by the change to the head is the seal

(item 4). Old style vapor seals will continue to be available to

¿WROGVW\OHKHDGV

Determination of new versus old style vapor seal is easy. Simply

look at the head design.

Impeller Housing change - PFM, PFP, PFV Series

Beginning August 2010, Finish Thompson made a change to

the impeller housing (item 18) on the plastic PF Series mod-

els (PFM, PFP, PFV). The change was phased in over several

months and covers all the various tube lengths within these

models.

The change affects these parts:
‡,QWDNHWXEHDVVHPEO\LWHP

‡8SSHULQQHUWXEHLWHP

‡,PSHOOHUKRXVLQJLWHP

When repairing a pump involving the parts listed above, you

must assure that the correct parts are ordered.
)LUVWFKHFNWKHVHULDOQXPEHU. If the pump serial number

ends in L10 or older (pumps manufactured before January

2011), it is necessary to determine which impeller housing is

installed in the pump. If the serial number is not legible, the

information below can be used to determine which impeller

housing your pump contains.
NOTE: All pump serial numbers end with a letter and two digit

number. The letters, A through L, refer to the month, e.g. A =

January. The two numerical digits refer to year. So, a pump se-

rial number ending in C08 was manufactured in March 2008.
Second - determine impeller housing required. The easiest

way to determine new versus old is to measure one of the two

"windows" in the side of the impeller housing. Measure from

the top to the bottom. Old style impeller housings have a win-

dow height of approximately .7" (18 mm). New style impeller

housings have a window height of approximately 1" (25 mm).

.7"/18 mm

1"/25 mm

Old Style

New Style

Impeller Housings

‡,IWKHSXPSKDVDQROGVW\OHLPSHOOHUhousing andRQHRU

all of the WKUHHDIIHFWHGSDUWVDUHUHTXLUHGIRUUHSDLU¿QG

the correct part number in the parts list on this page.
‡:KHQRUGHULQJDOORWKHUSDUWVUHIHUHQFHWKHSDUWVOLVWRQ

page 9 of this manual

Old Style Impeller

Item

Description

PFM/PFP

(Polypropylene)

PFV

(PVDF)

9

PF27 intake tube

M100005-1

M100005-5

9

PF40 intake tube

M100005-3

M100005-6

9

PF48 intake tube

M100005-4

M100005-7

9

PF60 intake tube

M100005-8

M100005-12

9

PF72 intake tube

M100005-11

M100005-10

11

PF27 upper inner tube

M100050-1

M100050-5

11

PF40 upper inner tube

M100050-3

M100050-6

11

PF48 upper inner tube

M100050-4

M100050-7

11

PF60 & PF72 upper inner tube

M100050-3

M100050-6

18

PF impeller housing

M100018-1

M100018-2

New Style

Old Style

To replace an old style head vapor seal, order P/N M100008.

Order P/N 107592 to replace a new style head lip seal. The

two seals are not interchangeable, so it is important to

order the correct part number.

Head

New style heads (item 5) are backwards compatible. Because

the seals are different between the two heads, the head is sold

as a kit that includes both the head and the seal. Use head

part numbers shown in the parts list on page 9 of this manual.

Heads

8

Old Style Impeller Housing Parts List

Item

Description

PFM/PFP

PFV

4

Vapor Seal*

M100008

M100008

9

27” Intake Tube

M100005-1

M100005-5

9

40” Intake Tube

M100005-3

M100005-6

9

48” Intake Tube

M100005-4

M100005-7

9

60” Intake Tube

M100005--8

M100005-12

9

72” Intake Tube

M100005-11

M100005-10

11

27” Upper Inner Tube

M100050-1

M100050-5

11

40” Upper Inner Tube

M100050-3

M100050-6

11

48” Upper Inner Tube

M100050-4

M100050-7

11

60” & 72” Upper Inner Tube

M100050-3

M100050-6

18

Impeller Housing

M100018-1

M100018-2

*Vapor seal can also be purchased as a kit with the bearing assembly using part

number 106567.

This manual is related to the following products: