1.3. COMPONENT DESCRIPTIONS, CONTINUED
1.3.3. Scale Pit
The scale pit is constructed of reinforced
concrete as detailed on the
Certified
Drawing Specifications.
•
The Tundra Scale requires a four foot
(4’) or deeper foundation.
─ Some states require a minimum of
four feet (48”) pit depth. Consult
with the local W&M for specifics in
your area.
•
The pit includes correctly positioned
piers with level surfaces for RC type
load cell base plates.
•
The ground rod(s) should be installed
before the pit floor is poured.
•
This System uses Intalogix™
Technology,
and requires two (2) pit ground rods.
1.3.4. Smart Sectional Controllers (SSCs)
The Smart Sectional Controllers (SSCs) used on Intalogix
™
Applications
are mounted
at each section using the supplied self-tapping screws and should be placed on the
cross members at installation.
•
Each Sectional Controller has four (4) water-tight gland bushings for cables.
•
The Pit Power Supply(ies) are mounted in the same manor.
─ Wiring diagrams for Sectional Controller(s) and Pit Power Supply(ies) are
in