Fairbanks HVX Series TALON SERIES Motor Truck Scale User Manual
Page 6
A. Introduction
This Instruction manual provides installation instructions for the Fairbanks Modular Steel
and Field-Pour model scales.
For correct Talon scale installation(s), use:
•
Methods and Procedures FF-2267 / 101732 (Appendix I)
•
The Certified prints/setting plans supplied with the scale
•
This Instruction Manual, 50785
The concrete foundation work must be performed according to the Certified prints issued
for the specific customer and order number. (The name and order number for the
particular customer will be on the prints.)
B. Description
The Modular Steel and Field Pour truck scales are available in various lengths and
widths. The scale is made up of modules of 10', 15', 20' or 23'-4" in length. All modules
are assembled and welded at the factory.
The scale should be located so that vehicles can approach and exit the scale as easily
as possible. The platform should be visible from the instrument location. Drainage of
surface water must be such that water does not collect under the scale. Smooth and
level approaches are required at each end of the platform to reduce loading shock and
facilitate testing of the scale. Approaches must conform to the requirements of the law in
the state in which the scale is being installed. In the absence of such laws the
approaches must conform to paragraph UR.2.6 National Institute of Standards and
Technology Handbook 44, which states that the first 10 feet must be level and on the
same plane as the scale platform.
C. Specifications
NTEP CC:
96-089A3
MC:
AM - 4949
Section 1: General Information
50785
6
04/12 Rev. 5