D. Replacing an RC load cell
1. Remove power from the instrument.
2. Lift the scale using a proper sized and rated hydraulic jack(s) at the corner(s) closet
to the defective load cell location.
3. Check upper and lower receiving cups, and "O" rings for damage. Replace as
necessary and reapply grease.
4. Insert the new cell into the upper receiving cup and position the anti-rotation pin.
5. Carefully lower the hydraulic jack(s) until the cell is set into the lower cup.
6.
Remove the cover of the SSC/Jct box, then loosen the gland bushing to free the
cable. Remove the old cell wires and connect new cell wires in the balance
Box/SSC. Secure the cover.
7. Test and adjust scale as necessary.
E. General Load Cell Information
Load Cell
Part No.
Description
Comments
70510
5½"
2 mV/V, 66k or 30t,1000 Ohm
80453
6"
2 mV/V, 100k 1000 Ohm
50785
31
04/12 Rev. 5