The Unirail contains two (2) potentiometers located in a sealed flexible

tube inside the frame. These are used to adjust the weight indication of

an individual loadcell, to enable the Unirail to display the same weight at

each end of its weigh rail. Testing should be performed using 500 lbs

suspended on a single roller hook. The hook is then moved from load

cell No. 1 and No. 2, and the weight indications are noted and

compared. A properly adjusted Unirail will have a maximum difference

of ½ lb between opposite ends with a 500 lb load.

Note:

The adjustment is intended to achieve equal readings, which may not

necessarily be correct and accurate. When complete, final calibration is

performed with the digital weight indicator.