After the Unirail is physically installed, install the digital weight indicator
per the appropriate service manual.
1. Attach the cable from the Unirail splice tube to the weight indicator as
follows:
Cable leads
Green
+ Excitation
Black
- Excitation
White
+ Signal
Red
- Signal
Shield
2. Attach a length of 18 gauge wire from the scale structure to a
suitable ground.
50019
12
03/12 - Rev. 8
G.
Wiring
+EX
-EX
+SIG
-SIG
SHLD
LO
ADCELL #2
E1
E2
+EX
-EX
+SIG
-SIG
SHLD
E3
E6
E7
E8
E9
LO
ADCELL #1
INNER
SHIELD
OUTER
SHIELD
R1
R2
NOTE:
LOADCELL CABLE LENGTH MUST BE IDENTICAL.
+EX (GREEN)
-EX (BLACK)
-SIG (RED)
+SIG (WHITE)