After the Unirail is physically installed, install the digital weight indicator

per the appropriate service manual.

1. Attach the cable from the Unirail splice tube to the weight indicator as

follows:

Cable leads

Green

+ Excitation

Black

- Excitation

White

+ Signal

Red

- Signal

Shield

2. Attach a length of 18 gauge wire from the scale structure to a

suitable ground.

50019

12

03/12 - Rev. 8

G.

Wiring

+EX

-EX

+SIG

-SIG

SHLD

LO

ADCELL #2

E1

E2

+EX

-EX

+SIG

-SIG

SHLD

E3

E6

E7

E8

E9

LO

ADCELL #1

INNER
SHIELD

OUTER
SHIELD

R1

R2

NOTE:
LOADCELL CABLE LENGTH MUST BE IDENTICAL.

+EX (GREEN)

-EX (BLACK)

-SIG (RED)

+SIG (WHITE)