Section 3: Scale Installation

08/12

13

51102 Rev. 7

INSTALLATION, CONTINUED

6. The scale is shipped with the threaded legs of the feet up tight against the load

cells. Remove the plugs at the corners of the scale and turn the feet clockwise a
minimum of four (4) complete turns with a large screwdriver.

7. Wire the scale cable to the proper type indicator, as shown in the chart below.

8. Once the scale platform is completely wired to the indicator, calibrate the unit.

Follow the appropriate indicator service manual to ensure a good calibration.

Platform Interface Cable Wiring

WIRE COLOR

FUNCTION

Black

(

) Excitation

Red

(+) Excitation

Yellow

Shield

Green

(+) Signal

White

(

)Signal