beautypg.com

Blagdon Pump B75 Non-Metallic User Manual

Page 19

background image

s30nmdl2sm-rev0312

Model B75 Non-Metallic Design Level 2 Page 19

2/07

Model B75 Non-Metallic Design Level 2 Page 16

FOR TPE EQUIPPED PUMPS
CONCEPT

The spill prevention option prevents

the air end components from being
contaminated or damaged when a
pumping diaphragm ruptures while
pumping caustic or toxic materials. It
also helps to protect the environment.
With the installation of optional leak
detectors (either mechanical or
electronic) the diaphragm rupture can be
detected. The pump can then be shut
down and repaired before any caustic or
toxic materials can enter the air end and
be exhausted into the surrounding
environment.

OPTION DIAPHRAGM SERVICING

To service the diaphragms first shut

off the suction, then shut off the
discharge lines to the pump. Next shut
off the compressed air supply, bleed the
pressure from the pump, and disconnect
the air supply line from the pump. Drain
any remaining pumped liquid from the
pump. Remove the pump before
servicing.

Next, drain the fluid from the spill

prevention chambers. This can be done
by removing the bottom plug (item 50)
from each spill prevention chamber.

After the fluid from the spill

prevention chambers has been drained,
the wet end components can now be
removed. See diaphragm servicing
section for detailed instructions. The spill
prevention option has two additional TPE
pumping diaphragms (item 46).

FILLING CHAMBERS WITH LIQUID

THE CHAMBERS ARE FILLED

WITH WATER AT THE FACTORY.

If you prefer to substitute another

liquid, to prevent system contamination
consult the factory first to determine
compatibility of the substitute with pump
construction.

Follow the steps listed here to replace

the liquid in the pump after disassembly
or liquid loss:

1. Drain the fluid in the spill

prevention chambers by removing the
bottom two boss plugs (items 50).
Replace the bottom two boss plugs after
the fluid is drained.

2. Remove the eight capscrews (item

11) fastening the discharge manifold and
elbows to the outer chambers (items 15).
The discharge manifolds and elbows can
now be removed.

3. Remove the top two boss plugs

(items 50). The spill prevention
chambers are filled through the exposed
ports.

4. Apply air pressure to the air

distribution valve. Install safety clip
(item 1-F) into the smaller unthreaded
hole in one end cap. This locks the valve
spool to one side, keeping the pump
from shifting.

5. Face the side of the pump with

the installed safety clip. If the safety clip
is installed in the top end cap, fill the
left spill prevention chamber. If the
safety clip is installed on the bottom end
cap, fill the right spill prevention
chamber.The volume of fluid is 3770 ml
(127.5 fl. oz.). It is important that the
exact amount of fluid is used.Too little

or too much fluid causes premature
diaphragm failure and erratic pumping.

6. Loosely reinstall one boss plug

to the filled spill prevention chamber.

7. Shut off air supply. Remove safety

clip. Adjust the air line regulator so that
air pressure slowly fills the pump. The
diaphragm expands, forcing the fluid in
the chamber to be slowly displaced.
When the pump shifts to the opposite
side, quickly install the safety clip.

8. Loosen the top boss plug on the

filled chambers. This allows fluid in the
chamber to purge trapped air from the
chamber. This can be seen by watching
the column of fluid in the sight tube. When
fluid appears at the top of the port,
quickly tighten the boss plug. Fluid loss
of 1 to 2ml is acceptable.

9. Tilt the pump so the uppermost

pipe tee (item 53) is in the vertical
position. Loosen the pipe plug (item 49).
This will allow trapped air to purge
through the pipe tee. When fluid appears
at the tee opening, reinstall the pipe
plug.

NOTE: If all air is not purged using

this procedure, remove the check valve
components from the top port of the outer
chamber (item 15). Apply manual
pressure to the pumping diaphragm by
inserting a blunt instrument into the top
port of the outer chamber and applying
pressure to the diaphragm. Loosen the
pipe plug (item 49) allowing the fluid to
purge any remaining trapped air.
Reinstall the plug.

10. Repeat steps 5 through 9 to fill

opposite spill prevention chamber.

Read these instructions

completely, before in-

stallation and start-up. It

is the responsibility of

the purchaser to retain

this manual for reference. Failure to

comply with the recommendations stated

in this manual will damage the pump, and

void factory warranty.

IMPORTANT

11. Reinstall the check valve

components, discharge manifold and
elbows to the pump. The pump is now
ready for operation.