beautypg.com

Step 7 thermostat test – A.O. Smith 120 trough 500 User Manual

Page 25

background image

BTR TANK TYPE HEATERS

SERVICE HANDBOOK

A.O. Smith Water Products

Service Handbook

Irving, Texas ©2000

Training Department

24

STEP 7

THERMOSTAT TEST

STEP 7.

THERMOSTAT TEST.

Set the thermostat to call for heat.

Using your

multimeter, test for 24 VAC between right terminal and ground.

IF

THEN

The meter does not read 24 VAC and the jumper wire
between the high limit and the thermostat is in place:

• Replace the thermostat

The meter reads 24 VAC:

• Go to step 8.

Note: If the high limit to thermostat jumper wire was disconnected earlier to simulate a satisfied
thermostat, reconnect the jumper to the terminals.

Note: A yellow wire from this thermostat terminal connects to the damper PC board.