beautypg.com

A.O. Smith 120 trough 500 User Manual

Page 20

background image

BTR TANK TYPE HEATERS

SERVICE HANDBOOK

A.O. Smith Water Products

Service Handbook

Irving, Texas ©2000

Training Department

19

TROUBLESHOOTING BTR WATER HEATERS

To troubleshoot a BTR water heater check that:

• 120 VAC is supplied to the heater

• the tank is full of water

• gas is supplied to the unit

STEP 1

TEST THE TRANSFORMER

STEP 1 - TO TEST THE TRANSFORMER - Using a multimeter, test for 24 VAC
between the secondary transformer terminals.

IF

THEN

The meter does not read 24 VAC:

• Check that the 120 VAC is supplied

from the On/Off Switch – if not, replace
switch.

• Check that the 120 VAC is supplied

from transformer.

The meter reads 24 VAC:

• Go to step 2.