FEC AFC1500 User Manual
Page 4
![background image](/manuals/345993/4/background.png)
AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)
PAGE 4 - 4
Chapter 4: Installation & Wiring
4.3 Input Power Connection
An auto sensing power supply allows for input power in the range of 100 ~ 220VAC single phase,
50/60 hertz. Adequate circuit protection must be provided. Recommended conductor size should be
a minimum of #18AWG.
Wiring Chart
Mating Connector
Manufacture:
Amp
Housing Part No.:
1-178128-4
Contact Part No.:
1-175218-3 (Qty.-3)
** To standardize components, FEC cable part
#FEB-1260 may be used due to the fact that
pin #2 is not connected internally.
4.4 RS485 Connection
The Multi-2 Unit uses an RS485 port to perform the communication operations with the AFC1500
Servo (SAN) Controllers. This port has two channels CH1 and CH2. CH1 is dedicated to handle all
preset data upload and download, fastening results monitoring and collection. Channel CH2 is a high
speed connection to all AFC1500 Servo Controllers. It controls all required commands to perform the
fastening cycle.
RS485 port specifications (RJ45)
Speed
9600, 19200, 38400 baud
Cable
Std Cat 5 Ethernet
Maximum number of
connected devices
31
Protocol
Proprietary
Operating Voltage
RS485 Standard
RS485 Wiring
Pin
Description
4
100 ~ 220VAC +/-15%
3
100 ~ 220VAC +/-15%
2
No Connection **
1
Frame Ground
NO Signal Name
Channel
1 TX+ / RX+
CH1
2 TX- / RX-
CH1
3 RX+
CH2
4 TX-
CH2
5 TX+
CH2
6 RX-
CH2
7 GND
8 GND
1
8
4
3
2
1