AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)
PAGE 4 - 16
Chapter 4: Installation & Wiring
Out Port 1
These signals will output when the fastening sequence reaches a step that
has a [PLC OUTPUT] instruction inserted. Used to provide sequence
operation status to external PLC’s and/or control outputs for slide motion,
lights, & buzzers, etc without the use of a PLC. (The AFC User Console
Software can set these outputs on and off in the fastening sequence)
Out Port 2
Out Port 3
Out Port 4
Out Port 5
Out Port 6
Out Port 7
Out Port 8
Spindle in Bypass
Signal is active when any of the connected spindles are bypassed either from
San Unit bypass input signals or from the San Unit bypass switch.
Current Limit Warning
Active when the high current limit has been exceeded. This can be used to
identify potential motor failure before total failure occurs by identifying high
current draws over what the typical current draw is for the application.
Always ON / OFF
Can be used to set outputs ON or OFF. Typically used in conjunction with
Bank Outputs to monitor which Bank is selected.
[Table 2 – Sequence Select Output]
Sequence
Output 3
Sequence
Output2
Sequence
Output1
Sequence
Output0
Selected Fastening
Sequence No.
OFF
OFF
OFF
OFF
1
OFF
OFF
OFF
ON
2
OFF
OFF
ON
OFF
3
OFF
OFF
ON
ON
4
¥
¥
¥
¥
¥
ON
ON
ON
OFF
15
ON
ON
ON
ON
16