ADC Soneplex P-61-743 User Manual
Page 6
![background image](/manuals/34162/6/background.png)
ADCP-61-743
• Issue 3 • September 2004
Page 6
2004, ADC Telecommunications, Inc.
1.1 DS3 MUX Compatibility
Refer to Table 1 for compatibility information for DS3 MUXs, test access units, and MPU/SCU
software versions.
Table 1. DS3 MUX, TAU/RTAU, and MPU/SCU Software Compatibility
DS3 MUX TYPE
TEST ACCESS
UNIT TYPE
MPU SOFTWARE
VERSION
SCU SOFTWARE
VERSION
FUNCTIONALITY
C1
TAU
5.1.1 or later
2.5 or later
TAU
C1
RTAU
5.1.1 or later
2.0 or later
NO TEST ACCESS
D1
TAU
5.1.1 or later
2.5 or later
TAU
D1
RTAU
5.2 or earlier
2.5 or earlier
NO TEST ACCESS
D1
RTAU
5.3
3.0 or later
RTAU
G1
TAU
5.1.1 or later
2.5 or later
TAU
G1
RTAU
5.2 or earlier
2.5 or earlier
NO TEST ACCESS
G1
RTAU
5.3
3.0 or later
RTAU
Refer to the Soneplex System Operation and Maintenance Manual listed under Related
Publications at the beginning of this manual for more information.
2 INSTALLATION
There are two installation procedures:
•
Initial Installation - This installation procedure applies to the first time an IBBC shelf
will be populated with a RTAU module.
• Maintenance Installation (Existing System) - This installation procedure applies to an
IBBC shelf that has already been populated with a RTAU module.
Please follow the appropriate procedure per your system configuration.