ADC Soneplex P-61-743 User Manual
Page 22
![background image](/manuals/34162/22/background.png)
ADCP-61-743
• Issue 3 • September 2004
Page 22
2004, ADC Telecommunications, Inc.
Table 3. RTAU Configuration Fields, continued
FIELD
TYPE
OPTIONS
DESCRIPTION
DEFAULT
BIT ERROR SETUP FIELDS
OVERVIEW: Bit errors can be injected by the RTAU using the Bit Error Set Up fields. These sections are display-only fields that are
only displayed when the line code setting is INTERNAL. The Status field always shows the current status if the line code is
INTERNAL, but the Error Counts and Elapsed Time fields only show a value when a measurement is being made.
Error Count
Input
Range of 0 to 1544
Select either Error Count or Error Rate for bit
error setup. Both cannot be set at the same time.
If single errors or a burst of errors is desired, set
the Error Count field to the number of errors to
insert. If the Error Count field is set, the
number of errors will be transmitted each time
the Enter key is pressed.
0
Error Rate
Toggle
OFF, 1E-3, 1E-4,
1E-5, 1E-6, 1E-7
Select either Error Count or Error Rate for bit
error setup. Both cannot be set at the same time.
If a steady error rate is desired, set the Error
Rate field which indicates the rate bit or frame
errors are injected.
OFF
Error Locn
Toggle
OVERVIEW: The Error Location field must be
set to either PAYLOAD or FBE if the count or
rate field is set. Pressing the Enter or Return
key will cause the RTAU to send the errors.
NONE
NONE
Indicates count is 0 and rate is off.
PAYLOAD
Bit errors are injected.
FBE
Frame Bit Error. Frame errors are injected.
Error Counts Data
Display
only
None
Eight-digit counter or blank.
Blank
Error Counts BPV
Display
only
None
Eight-digit counter or blank.
Blank
Error Counts Frame
Display
only
None
Eight-digit counter or blank.
Blank
Error Counts CRC
Display
only
None
Eight-digit counter or blank.
Blank
Error Counts COFA
Display
only
None
Eight-digit counter or blank.
Blank
Status F Sync
Display
only
None
* or blank
Blank
Status P Sync
Display
only
None
* or blank
Blank
Status RAI
Display
only
None
* or blank
Blank
(continued)