Filters and maintenance

Extractor hoods with two filter cartridges:

Warning: The halogen bulbs must be swit-
ched off and cool.

1. Depress the detent on the grease filters

in the direction of the arrow and fold
down the grease filter slightly. Detach
the grease filter by pulling it towards
yourself.

2. Clean the grease filters.

3. Re-insert the clean grease filters.

Removing and installing the activa-
ted carbon filter

Extractor hoods with a filter mat:

1. Remove the filter; see grease filter.

❑ The wire grille is no longer required

when an activated carbon filter is
installed.

2. Place the activated carbon filter on the

filter mat and clamp it in.

3. Install the filter frame.

❑ See grease filter.

Activated carbon filter