TUMBLER ENCLOSURE CONSTRUCTION

IMPORTANT: DO NOT block the airflow at the rear
of the tumbler with laundry or other articles. Doing
so would prevent adequate air supply to the
combustion chamber of the tumbler.

A typical tumbler enclosure is shown in Figure 2. Note
that the enclosure touches the tumbler top and side
panels. Also, note the minimum and maximum
dimensions. Be aware that there may be local codes and
ordinances which must be complied with.

IMPORTANT: Install tumblers with sufficient
clearance for servicing and operation. Refer to
Figure 2.

Figure 2

To reduce the risk of serious injury, install
lockable door(s) to prevent public access
to rear of tumblers.

W055

WARNING

0" CLEARANCE

NOTE: Shaded areas
indicate adjacent
structure.

0" CLEARANCE PERMITTED

FOR FIRST 4" (10.16 cm)

4" (10.16 cm)

MAXIMUM

12" (30.5 cm)

MINIMUM

CLEARANCE

PERMITTED

FOR REMAINDER

GUARD

24" (61 cm) MINIMUM

36" (91.4 cm) RECOMMENDED

FOR MAINTENANCE PURPOSES

PROVISION

FOR

MAKE-UP

AIR

T038IE3D

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances.

W056

WARNING

Minimum Recommended Clearances

Model

Top
First 4" (10.2 cm)

Top
(Remainder)

Back

Sides

28"

0" (0.0 cm)

12" (30.5 cm)

24" (61 cm)

0" (0 cm)

31.5"

0" (0.0 cm)

12" (30.5 cm)

24" (61 cm)

0" (0 cm)