Electrical requirements for 31.5" wide tumblers – Alliance Laundry Systems 105 User Manual
Page 37
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
M414545
35
ELECTRICAL REQUIREMENTS
For 31.5" wide Tumblers
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a qualified electrical contractor in accordance with all
applicable local and national requirements.
NOTE: DO NOT use aluminum wire.
* Current Ratings vary slightly depending on model, see nameplate.
Table 7
Heat Source
Serial Plate Voltage
Terminal Block
Connections Required
Rated
Current
Breaker
Rating
Breaker
Poles
Recommended
Wire Size
Steam CSL
120V/60Hz/1ph
L1, Neutral and ground
*
20 Amps
1
12 AWG
Gas & CSH
120V/60Hz/1ph
L1, Neutral and ground
*
15 Amps
1
14 AWG
Gas & Steam
208 or 240V/60Hz/1ph
L1, L2 and ground
*
15 Amps
2
14 AWG
Gas & Steam
230-240V/50Hz/1ph
L1, Neutral and ground
*
15 Amps
1
14 AWG
Gas & Steam
208 or 240V/60Hz/3ph
L1, L2, L3, and ground
*
15 Amps
3
14 AWG
Gas & Steam
380 or 415V/50Hz/3ph
L1, L2, L3, and ground
*
15 Amps
3
14 AWG
Gas & Steam
460-480V/60Hz/3ph
L1, L2, L3, and ground
*
15 Amps
3
14 AWG
Electric
208V/60Hz/1ph
L1, L2, and ground
104 Amps
125 Amps
2
0 AWG
Electric
240V/60Hz/1ph
L1, L2, and ground
92 Amps
100 Amps
2
2 AWG
Electric
240V/50Hz/1ph
L1, Neutral and ground
90 Amps
100 Amps
1
2 AWG
Electric
208V/60Hz/3ph
L1, L2, L3, and ground
62 Amps
70 Amps
3
4 AWG
Electric
240V/60Hz/3ph
L1, L2, L3, and ground
55 Amps
60 Amps
3
4 AWG
Electric
240V/50Hz/3ph
L1, L2, L3, and ground
53 Amps
60 Amps
3
4 AWG
Electric
380V/50Hz/3ph
L1, L2, L3, and ground
33 Amps
40 Amps
3
8 AWG
Electric
415V/60Hz/3ph
L1, L2, L3, and ground
30 Amps
35 Amps
3
8 AWG
Electric
480V/60Hz/3ph
L1, L2, L3, and ground
28 Amps
35 Amps
3
8 AWG