Aegis 4000 quick reference guide – Pach and Company AeGIS 4000_4000RT Manual User Manual
Page 37

1. To place a call from the AeGIS 4000: Press #.
2. To grant access to a visitor: Press 9 (door 1) or
Press 8 (door 2).
3. To use a personal access code: Press * then release,
and press 4-digit access code.
4. To extend a talk time: tenant must press # after hearing
the time-out warning beep.
5. To enable call forwarding:
Local press 0 and * simultaneously then release then
select 71(call forwarding on 71) or 72 (call forwarding on
72) then press #.
Premise phone lift the handset wait for dial tone then
press ## then select 71(call forwarding on 71) or 72 (call
forwarding on 72) then press #.
Remote phone lift the handset wait for dial tone then
press # and4-digit master code then select 1(call forwarding on
71) or 2 (call forwarding on 72) then press #.
6. To open and Closed, to open and hold open and then
closed door 1 or door 2, see table on the right
AeGIS 4000 QUICK REFERENCE GUIDE
Log into programming mode
1. Press # and 0 simultaneously, screen will stop scrolling. Repeat this step if screen is still scrolling.
2. Enter the 4-digit master code (default master code is 0000).
3. Select the function code from the table below.
Function Code
Description
Function Code
Description
*
Exit the programming or hang-up the call.
76
Delete phone number on 70, 71 and 72
#
Save program or inniate a call.
87
Disable or Enable automatic call
forwarding. 0=disabled 1=enabled
DEFAULT= DISABLED
*
and #
Turn power off then press and hold these keys,
turn the power on.
88
Select automatic call forwarding phone number
on 71 or 72.
00
Change system master code
DEFAULT MASTER CODE=0000
89
Select automatic call forwarding time or hang-
up time (15-90 seconds)
DEFAULT= 15 SECONDS
01-20
Individual access code for relay #1
Maximum 20 codes
90
Manual closed or open door #1
1= open 0= closed
21-40
Individual access code for relay #2
Maximum 20 codes
91
Manual closed or open door #2
1= open 0= closed
41-50
Individual access code for relay #1 & #2
Maximum 10 codes
92
Talk time (10-90 seconds)
DEFAULT=60 SECONDS
51
Relay #1 open time interval (01-90 sec)
DEFAULT= 12 SECONDS
93
Lock-out count (03-09)
DEFAULT=3 TRIES
52
Relay #2 open time interval (01-90 sec)
DEFAULT= 12 SECONDS
94
Auxiliary Mode, 0=disabled, 1=enabled control
by door open interval 2=enabled control by AUX
DEFAULT= 0 (disabled)
60
Delete all access codes 01-20
95
Alarm mode
DEFAULT= 10 Sec (local) 30 Sec (remote)
61
Delete all access codes 21-40
96
System answer mode (0= disabled,
1,2,3,...9 = enabled)
DEFAULT=DISABLED
62
Delete all access codes 41-50
97
Do not disturb mode (0= disabled 1= enabled)
DEFAULT=DISABLED
65
Delete all access codes
98
Select initiating premise call key
0= # 1= *
DEFAULT=#
70
Direct call forwarding phone number up to 11-
digit. Intercom mode is Off.
99
Set memory to factory default.
71-72
Auto or manual call forwarding phone
number up to 11-digit. Must be enabled.
SYSTEM OPERATION
LOCAL
PREMISE PHONE
REMOTE PHONE
1.Press 0 and #
simultaneously then
release
2. Enter 4-digit
master code then #
3. PRESS
90 (door 1) or
91 (door 2), then #
you will hear “one
short beep”
4. PRESS 1THEN #
TO OPEN or
PRESS 0 THEN #
TO CLOSED.
• Press ##, you will
hear “One short
beep”.
• Press
For Door 1
9 to open and closed
8 to open and hold
open
7 to closed
For Door 2
5 to open and closed
4 to open and hold
open
3 to lock
• Call the system, you
will hear “One short
beep”.
• Press # then the 4-
digit master code.
• Press
For Door 1
9 to open and closed
8 to open and hold
open
7 to closed
For Door 2
5 to open and closed
4 to open and hold
open
3 to lock