Troubleshooting, Common installation for an 8 channel configuration – Nitek FSS20811S User Manual
Page 3
Troubleshooting
Problem: No video present
1. Is the Power LED in the device illuminated?
Answer — No
Check to insure power adapter is properly connected to the device
and power outlet.
Is the correct 5V DC adaptor that was supplied with the unit being
used?
Contact tech support at Nitek
2. Is the LED for fiber connection in the device FLASH?
Answer — Yes
Check the fiber connection to both transmitter and receiver.
Check the SC fiber connector on both transmitter and receiver is clean and properly connected to the fiber cable.
Contact tech support at Nitek
3. Is the LED for video connection in the device illuminated?
Answer — No
Check the camera for a video output.
Check the video cable connection between the camera and the transmitter and also the monitor and the receiver.
Check the BNC connector on both transmitter and receiver is clean and properly connected to the video cable.
Contact tech support at Nitek
LED INDICATORS
LED
STATUS
PWR
On - Normal Operation, unit powered-up
Off - Check power supply
VIDEO *
Glows - With Video Luminance
Tx
Blinks - Normal when data is transmitted
Rx
On - No Fiber Connection
Blinks - Normal when data is received
* Receiver Blinks rapidly with NO Fiber Connection
Common Installation for an