Quick start – DoorKing 1819 Information Phone User Manual
Page 5

1819-065-B-4-07
Page
5
Mount the Telephone Entry System. If the unit is being used to provide access through an
automated vehicular gate, the unit must be mounted at least 10-feet away from the gate.
See pages 11-13.
1
2
Connect 16 VAC power to terminals 13-14. Connect a dedicated touch-tone loop-start
phone line to terminals 1-2. Connect ground wire to terminal 3.
See pages 15-18.
3
Program a MASTER CODE ( Section 3.1.1) - Factory Default is 9999
1. Open the cabinet and turn the Master Code switch ON.
2. Enter a four-digit Master Code on the keypad and then press *.
3. Turn the Master Code switch OFF.
4
5
Program Phone Number ( Section 3.2.1)
1. Press *01 and enter Master Code.
2. Enter 001 then press *.
3. Enter a 7-digit Phone Number then press *.
4. Press 0# TOGETHER when finished.
QUICK START
6
Connect device(s) to be activated (gate operator, door strikes, etc.) to relay terminals as
required.
See pages 17-18.
Adjustments ( Section 2.4)
1. Make a phone call.
2. Adjust microphone volume**, speaker volume and feedback.
3. Have tenant press 9 to open door or gate.
** Rev H boards and higher only.