beautypg.com

Dixon Valve 100 TON RAM Complete Manual User Manual

Page 65

background image

Internal Expansion of H520 Couplings

customer service

800

355

1991

1

Section 9

100 Ton Ram Instruction Manual

Before you begin, move the directional control lever
to the "FORWARD” position, depress the button on
the remote and fully extend the ram cylinder. Return
the directional control lever to the “NEUTRAL”
position. Select the proper Pull Rod.
For 1" through 1 1/2" use

25RODSMALL For 2"

through 4" use

25RODLARGE

Screw the short threaded end of the rod or the rod
adapter into the IX Master Bar.

Install the Master IX Adapter (001-0072) into the Die
Bed Plate (0010-001). Secure in place using two
Adapter Straps (001-0072A) and 3/4" - 10 UNC x 8"
rods.

Select the corresponding Thrust Plate for the size
fitting you are installing. Assuring that the recess is
facing outward toward the operator, slide the Thrust
Plate over the Pull Rod until it reaches the
100ROSTPA. Align the holes in the Thrust Plate
with the dowel pins on the 100ROSTPA and slide
the Thrust Plate over the pins. Tighten the wing nut
to lock in place.

3

2

4

1

(

refer to the

Converting the 100 Ton Ram from Swaging to Internal Expansion section of the instruction manua

l)

Install the 100ROSTPA into the Master IX Adapter
opening and secure with Adapter Straps (001-
0072A
) and two 1/2" - 13 UNC Hex Bolts 1-5/8"
long.