Dixon Valve 100 TON RAM Complete Manual User Manual
Page 65
![background image](/manuals/339335/65/background.png)
Internal Expansion of H520 Couplings
customer service
800
•
355
•
1991
1
Section 9
100 Ton Ram Instruction Manual
Before you begin, move the directional control lever
to the "FORWARD” position, depress the button on
the remote and fully extend the ram cylinder. Return
the directional control lever to the “NEUTRAL”
position. Select the proper Pull Rod.
For 1" through 1 1/2" use
25RODSMALL For 2"
through 4" use
25RODLARGE
Screw the short threaded end of the rod or the rod
adapter into the IX Master Bar.
Install the Master IX Adapter (001-0072) into the Die
Bed Plate (0010-001). Secure in place using two
Adapter Straps (001-0072A) and 3/4" - 10 UNC x 8"
rods.
Select the corresponding Thrust Plate for the size
fitting you are installing. Assuring that the recess is
facing outward toward the operator, slide the Thrust
Plate over the Pull Rod until it reaches the
100ROSTPA. Align the holes in the Thrust Plate
with the dowel pins on the 100ROSTPA and slide
the Thrust Plate over the pins. Tighten the wing nut
to lock in place.
3
2
4
1
(
refer to the
Converting the 100 Ton Ram from Swaging to Internal Expansion section of the instruction manua
l)
Install the 100ROSTPA into the Master IX Adapter
opening and secure with Adapter Straps (001-
0072A) and two 1/2" - 13 UNC Hex Bolts 1-5/8"
long.