proTK™
Neutron Flux Instrumentation
www.mirion.com
145023EN-C
DAK 250 Digital Start-Up Channel
●
For the pulse range (DAK 250-i) with pulse detec-
tors and for the intermediate range (DAK 250-g) with
ionization chambers with linear or logarithmic output
signal and reactor period signal, optional module for
reactivity calculation
DGK 250 Digital Power Range Channel
●
For processing and numeric calibration of one or two
signal paths with boron coated ionization chambers
DSK 250 Local Power Range Channel
●
With four signal paths for in-core fi ssion chambers in
the BWR
DWK 250 Digital Wide Range Channel
●
For combination of pulse and Campbell (RMS) signal
processing together with in-core (BWR) or ex-core
(PWR) fi ssion chambers with pulse, intermediate, and
wide range fl ux signal and reactor period signal
DLK 250 Power Distribution Channel
●
For monitoring the in-core fl ux distribution in PWRs
with three or six signal paths for in-core SPN-detec-
tors
DMK 250 Average Power Range Channel
●
Together with the DSK 250 for the average fl ux and
fl ow related fl ux calculation in the BWR and for core
oscillation monitoring
The signal processing system TK 250 includes neutron fl ux monitoring channels for BWR and PWR, and for research
reactors, which are designed and qualifi ed for applications within the reactor protection system:
Architecture of TK 250
signal processing channels
for neutron fl ux monitoring