beautypg.com

Health physics division, Description, 3 sided lead shielding – Mirion Technologies SPIR-Ident Pedestrian GN User Manual

Page 2: Remote cameras control option, With or without occupancy signal functions, Gamma detection and identification capability, Neutron detection capability, Ethernet (network) connectivity dimensions

background image

Health Physics

Division

Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.

Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179

Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18

Mirion Technologies (RADOS) Oy

P.O. Box 506
FIN-20101 Turku
Finland

T +358 2 468 4600
F +358 2 468 4601

Mirion Technologies (RADOS) GmbH

Ruhrstrasse 49
DE-22761 Hamburg
Germany

T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256

Mirion Technologies Shanghai Branch

Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924

SPIR-IDENT PEDESTRIAN GN

Detection and Identification - Risks Prevention

www.mirion.com

145396EN-E

DESCRIPTION

1 to 4 detection pillars including each a 2 or 4 liter
NaI(Tl) gamma detector and 1 or 2 moderated He3 or
BF3 neutron detectors

3 sided lead shielding

Each gamma detector is associated with a fast digital
spectrometer

Standard or Panel PC with SPIR-IDENT Server software,
Portal and Expert mode interface

Includes SIA identification algorithm designed for
challenging Homeland Security issues

Remote cameras control option

With or without occupancy signal

FUNCTIONS

0,5 second continuous elementary spectra acquisition
and stabilization (sourceless)

Count rate and dose rate calculation, alert criteria
monitoring

Self-triggered spectra accumulation capability if alert

Real-time identification per channel and group of
channels

Automated results and pictures capture every half
second during alarms

Sliding spectra analysis between occupancies to
monitor background

Manually triggered static mode available for
identification confirmation

PERFORMANCES

Isotope list:
according to ANSI N42-38, IEC, IAEA standards
Industrial, SNM, Medical and NORM radionuclides

Gamma detection and identification capability:

according to configuration, designed to exceed ANSI
N42-38 for pedestrian in dynamic mode

includes special processing for masked Isotopes such
as SNM masked by medicals or NORMs

Neutron detection capability:

according to configuration, designed to exceed ANSI
N42-38 / IAEA recommendation for pedestrian in
dynamic mode

COMMUNICATION

Ethernet (network) connectivity

DIMENSIONS

Body: 148 x 50,2 x 22,2 cm (57 x 19,73 x 8,74 in)

Base: Ø 32 cm (12.6 in)

Weight: 62 kg (137 lb)

Expert interface display

Portal interface display

Graphic «waterfall» display