Health physics division – Mirion Technologies SPIR-Ident Mobile User Manual
Page 2
Health Physics
Division
Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Mirion Technologies Shanghai Branch
Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924
Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.
SPIR-IDENT MOBILE
Detection & Identification - Risks Prevention
www.mirion.com
144208EN-E
DESCRIPTION
●
1 to 4 detection units including 1 or 2 NaI(Tl) detectors
(2 or 4 liter), MCAs and optional neutron detectors
●
1 interface unit with WiFi or wire PC link
batteries, charger, DC and AC power supply
●
Ruggedized tablet PC with GPS and wireless
communication
●
SIA identification algorithm designed for challenging
Homeland Security and nuclear accident fallout issues
●
Simplified SpirMOBILE interface, based on Google
Earth or georeferenced views or maps
●
Data export to ESRI Geographical Information System
●
Optional altitude acquisition module
●
Option: Remote transmission to commander station
FUNCTIONS
●
0.5 or 1 second continuous elementary spectra acqui-
sition and stabilization (sourceless)
●
Count rate/dose rate profile display
●
Single or multi channels parallel operation
●
Continuous sliding spectra identification.
●
Alarm filtering according customer criteria
●
Simplified panel display (level/ ID; instant or trend)
●
Expert display (spectra, trend, raw and filtered ID)
●
Mapping: trajectory with level indication and alerts
locations flags
●
Georeferenced database and replay capability
PERFORMANCES
●
≤ 8 % energy resolution and 37 cps per nSv/h sensitivity
for Cs-137 (661 keV) gamma radiation (typical values
for 4 l NaI(Tl))
●
1024 channels fast MCA, one per detector
●
Energy range 30keV to 3 MeV
●
Identification up to 4 isotopes mixed (in addition of
background), with confidence level and quantification
indication
●
Isotopes list according ANSI N42-34, N42-38,
IEC62327, IEC 62484 draft, IAEA Tecdoc
●
User selectable alarm criteria
●
User calibration for quantification output
CHARACTERISTICS
●
Polyester resin strengthened, glass fiber containers
●
Size:
○
Single detector case: 84 cm x24 cm x24 cm (33 in x9
in x9 in), 18 kg (39.7 lb) (with 2 l NaI(TI)), 24 kg (52.9 lb)
(with 4 l NaI(TI))
○
Double detector case: 90 cm x42 cm x33 cm (35 in
x16 in x13 in), 35kg (77 lb) (with 2 l NaI(TI)), 49 kg (108
lb) (with 4 l NaI(TI))
○
Interface case: 90 cm x43 cm x33 cm (35 in x17 in x13
in), 20 kg (44 lb)
○
Roof case for 4 detectors (2 l): 195 cm x130 cm x50 cm
(76 in x51 in x19 in), 120 kg (264.5 lb)
●
Operating temperature range:
○
-20°C to +50°C (-68°F to +122°F), temperature shock
protected
●
Power supply: vehicle 10-30 VDC or main 85- 264
VAC
NORM:
40K, 226Ra and daughters, 232Th
and daughters
Medical:
18F, 51Cr, 67Ga, 99Mo , 99mTc,
103Pd, 111In, 123I, 125I, 131I,
133Xe, 153Sm, 201Tl
Industrial and
Nuclear Accident:
22Na, 57Co, 60Co, 75Se, 106Rh,
132I, 133I, 133Ba, 134Cs, 137Cs,
152Eu, 192Ir, 241Am
SNM:
233U, 235U, 238U, 239Pu, 241Pu,
237Np
Double detector case
Interface case
Roof case
Installation in a
helicopter