beautypg.com

Health physics division – Mirion Technologies SPIR-Ident Mobile User Manual

Page 2

background image

Health Physics

Division

Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.

Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179

Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18

Mirion Technologies (RADOS) Oy

P.O. Box 506
FIN-20101 Turku
Finland

T +358 2 468 4600
F +358 2 468 4601

Mirion Technologies (RADOS) GmbH

Ruhrstrasse 49
DE-22761 Hamburg
Germany

T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256

Mirion Technologies Shanghai Branch

Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924

Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.

SPIR-IDENT MOBILE

Detection & Identification - Risks Prevention

www.mirion.com

144208EN-E

DESCRIPTION

1 to 4 detection units including 1 or 2 NaI(Tl) detectors
(2 or 4 liter), MCAs and optional neutron detectors

1 interface unit with WiFi or wire PC link

batteries, charger, DC and AC power supply

Ruggedized tablet PC with GPS and wireless
communication

SIA identification algorithm designed for challenging
Homeland Security and nuclear accident fallout issues

Simplified SpirMOBILE interface, based on Google
Earth or georeferenced views or maps

Data export to ESRI Geographical Information System

Optional altitude acquisition module

Option: Remote transmission to commander station

FUNCTIONS

0.5 or 1 second continuous elementary spectra acqui-
sition and stabilization (sourceless)

Count rate/dose rate profile display

Single or multi channels parallel operation

Continuous sliding spectra identification.

Alarm filtering according customer criteria

Simplified panel display (level/ ID; instant or trend)

Expert display (spectra, trend, raw and filtered ID)

Mapping: trajectory with level indication and alerts
locations flags

Georeferenced database and replay capability

PERFORMANCES

≤ 8 % energy resolution and 37 cps per nSv/h sensitivity
for Cs-137 (661 keV) gamma radiation (typical values
for 4 l NaI(Tl))

1024 channels fast MCA, one per detector

Energy range 30keV to 3 MeV

Identification up to 4 isotopes mixed (in addition of
background), with confidence level and quantification
indication

Isotopes list according ANSI N42-34, N42-38,

IEC62327, IEC 62484 draft, IAEA Tecdoc

User selectable alarm criteria

User calibration for quantification output

CHARACTERISTICS

Polyester resin strengthened, glass fiber containers

Size:

Single detector case: 84 cm x24 cm x24 cm (33 in x9
in x9 in), 18 kg (39.7 lb) (with 2 l NaI(TI)), 24 kg (52.9 lb)
(with 4 l NaI(TI))

Double detector case: 90 cm x42 cm x33 cm (35 in
x16 in x13 in), 35kg (77 lb) (with 2 l NaI(TI)), 49 kg (108
lb) (with 4 l NaI(TI))

Interface case: 90 cm x43 cm x33 cm (35 in x17 in x13
in), 20 kg (44 lb)

Roof case for 4 detectors (2 l): 195 cm x130 cm x50 cm
(76 in x51 in x19 in), 120 kg (264.5 lb)

Operating temperature range:

-20°C to +50°C (-68°F to +122°F), temperature shock
protected

Power supply: vehicle 10-30 VDC or main 85- 264
VAC

NORM:

40K, 226Ra and daughters, 232Th

and daughters

Medical:

18F, 51Cr, 67Ga, 99Mo , 99mTc,

103Pd, 111In, 123I, 125I, 131I,

133Xe, 153Sm, 201Tl

Industrial and
Nuclear Accident:

22Na, 57Co, 60Co, 75Se, 106Rh,

132I, 133I, 133Ba, 134Cs, 137Cs,

152Eu, 192Ir, 241Am

SNM:

233U, 235U, 238U, 239Pu, 241Pu,

237Np

Double detector case

Interface case

Roof case

Installation in a
helicopter