Health physics division – Mirion Technologies SPIR-Ident Mobile Light User Manual
Page 2

Health Physics
Division
Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Mirion Technologies Shanghai Branch
Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924
DESCRIPTION
●
1 detection unit including 1 NaI(Tl) detector (2 or 4 liters),
digital MCA
●
1 ruggedized tablet PC
●
1 GPS, WAAS and EGNOS compatible
●
SIA identification algorithm designed for challenging
Homeland Security and nuclear accident fallout issues
●
Simplified SpirMOBILE interface, based on Google
Earth or georeferenced views or maps
●
Data export to ESRI Geographical Information System
●
SpirPORTAL interface for deployable portal use
FUNCTIONS
●
0.5 or 1 second continuous elementary spectra acquisi-
tion and stabilization (sourceless)
●
Count rate/dose rate profile display
●
Continuous sliding spectra identification
●
Alarm filtering according customer criteria
●
Simplified panel display ( level/ ID; instant or trend)
●
Expert display ( spectra, trend, raw and filtered ID)
●
Mapping: trajectory with level indication and alerts
locations flags
●
Georeferenced database, replay and data export
capabilities
PERFORMANCES
●
Typical 4 liters detector: for
137
Cs, 8%
resolution and 37cps per nSv/h sensitivity
●
1024 channels fast MCA, one per detector
●
Energy range 25 keV to 3 MeV
●
Identification up to 4 isotopes mixed (in addition to
background), with confidence level and quantification
indication
●
Isotopes list according to ANSI N42-34, N42-38,
IEC62327, IEC 62484 draft, IAEA Tecdoc
●
User selectable alarm criteria
CHARACTERISTICS
●
Polyester resin strengthened with glass fiber containers
●
Size:
○
Single detector case: 84 cm x24 cm x24 cm (33 in x9
in x9 in), 18 kg (39.7 lb) (with 2 l NaI(TI)), 24 kg (52.9 lb)
(with 4 l NaI(TI))
●
Operating temperature range:
○
-20°C to +50°C (-68°F to +122°F), temperature shock
protected
●
Detector unit power supplied by the tablet PC
SPIR-IDENT Mobile light
Detection & Identification - Risks Prevention
www.mirion.com
149026EN-C
NORM:
40K, 226Ra and daughters, 232Th and
daughters
Medical:
18F, 51Cr, 67Ga, 99Mo , 99mTc, 103Pd,
111In, 123I, 125I, 131I, 133Xe, 153Sm, 201Tl
Industrial
and Nuclear
Accident:
22Na, 57Co, 60Co, 75Se, 106Rh, 132I, 133I,
133Ba, 134Cs, 137Cs, 152Eu, 192Ir, 241Am
SNM:
233U, 235U, 238U, 239Pu, 241Pu, 237Np