Health Physics
Division
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
Lieu-Dit Calès
Route d‘Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies
(RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 4684 600
F +358 2 4684 601
Mirion Technologies
(RADOS) GmbH
Ruhrstrasse 49
D-22761 Hamburg
Germany
T +49 40 85193 0
F +49 40 85193 256
Mirion Technologies Shanghai Branch
Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924
RADOS CheckIn-Clean™
CheckPoint:Gate™ family
7NUC_CkInClean_Y016-010E_2_FL
Overview of Features
Detection
• Large surface scintillation detectors for beta/gamma radiation
• Two-step measurement
• Differentiation between surface contamination and internal contamination
• Background compensation with a unique method using two median filters
• Measurements in cps, dpm, cpm, Bq, nCi, Bq/cm
2
, kBq/m
2
User interface
• Display of amount of activity and position of contamination
• User guidance by speech processor up to four languages user selectable (as an option)
• Monitoring of the measurement position by optical sensors
Option: rugged construction model available - designed for combat conditions
• Special fixings
• Hardened to withstand high mechanical impacts or shocks
• Smaller size monitor to fit into transport containers
Option: replacement of thorax detectors with detectors of increased gamma sensitivity
combined with scales for consideration of background suppression
Customer Benefits
High throughput
• Software on the basis of the real-time QNX operating system proven in many generations
of RADOS monitors
• Option: P
2
accelerator reduces measurement time up to 30 %
Low cost of operation and maintenance
• No gas required for operation and no delay after maintenance due to gas flushing
• Lower rate of damage to detectors in day to day wear
• Standard RADOS calibration tools
• Very easy adjustment of all programmable parameters
Ability to network
• TCP/IP ability
• Option: link up with CeMoSys™ server for centralised monitoring
references
RADOS contamination monitors have been proven over many generations of RADOS
body monitors. The CheckIn-Clean™ monitor of the CheckPoint:Gate™ family is the ideal monitor
to complement security checks at the entry points from controlled areas in nuclear facilities.
The CheckIn-Clean™ is also very well suited for source and contamination scanning in special situations
such as post accident or conflict situations with radioactive components.