Health physics division, Measurement and display, Display units: msv, μsv or mrem – Mirion Technologies DMC 2000S User Manual
Page 2: Linearity, X and gamma energy range: 50 kev to 6 mev, Accuracy: <± 10, Weight with battery: < 56 g (1.9 oz), Worn by a replacable clip
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technolgies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Health Physics
Division
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
DMC 2000S
Active Dosimetry - Dosimeters
www.mirion.com
144269EN-C
PHYSICAL CHARACTERISTICS
Compliant to IEC 1283, ANSI 4220A
●
PTB approved version, compliant with IEC61526 ed2
●
Measurement and display:
●
display units: mSv, μSv or mrem
○
dose: 1 μSv to 10 Sv (0.1 mrem to 1000 rem)
○
display rate: 0.01 mSv/h to 10 Sv/h or 0.001 mSv/h to
○
10 Sv/h (extended option)
measurement range: 0.1 μSv/h to 10 Sv/h
○
Linearity:
●
<± 20 % up to 1 Sv/h (100 rem/h)
○
<± 30 % up to 10 Sv/h (1000 rem/h)
○
X and gamma energy range: 50 keV to 6 MeV
●
Accuracy: <± 10 % (
●
137
Cs, ~ 25 mSv/h including ± 5 %
extended uncertainty K=2)
ELECTRICAL CHARACTERISTICS
Standard calculator battery LiMnO
●
2
CR2450, one year
battery life (typical, 8h per day in run mode)
MECHANICAL CHARACTERISTICS
Dimensions: 87 x 48 x 28 mm (3.4 x 1.9 x 1.1 in) with clip
●
Weight with battery: < 56 g (1.9 oz)
●
Worn by a replacable clip
●
ENVIRONMENTAL CHARACTERISTICS
Temperature range: -10°C to 50°C (14°F to 122°F)
●
Humidity: < 90 % at 42°C (108°F)
●
Storage: -30°C to 71°C (-22°F to 160°F)
●
Shock, vibration and drop resistant, waterproof IP67
●
EMC: complies and exceeds standards by a large margin
●
Factory calibration approved under ISO/CEI 17025
●
The histogram enables events to be reconstructed in detail.
Radiological supervisors can then analyze the data surroun-
ding an incident.
Histogram are saved to non-volatile memory (EEPROM)
●
workers dose stored in increments of 10 s, 1 min,10
●
min or 24 hours with compression of consecutive zero
dose intervals
Event log (alarms, faults, changes) marks events during
●
the selected time period
Time and data of passage with sub-zone notation
●
Stores data for several consecutive workers’ entries
●
and exits (up to 700 steps version 2 and up to 3800
steps version 3)
Technician using the hands-free
capability of the DMC 2000 S
with LDM 2000 reader.
Low battery: 9 hours
remaining
Dose rate display
Dose and alarm
Accumulated dose display
Hp