RAD-60 Personal Alarm Dosimeter
Active Dosimetry
20996027_RAD60_EN_A
TECHNICAL SPECIFICATIONS:
Physical characteristics
Radiation detected:
•
gamma and X-rays
Detectors:
•
energy compensated Si-Diode
Measurement range:
•
- dose: 1 µSv - 9.99 Sv or 0.1 mrem - 999 rem
- dose rate: 5 µSv/h - 3 Sv/h or 0,5 mrem/h - 300 rem/h
Calibration:
•
better than ±5% (Cs-137, 662 keV at 2 mSv/h), Hp(10)
Energy response:
•
Hp(10), 60 keV - 3 MeV, better than ±25%, up to 6 MeV, better than ±35%
Dose rate linearity:
•
better than ±15%, up to 3 Sv/h (300rem/h)
Audible alarms:
•
- eight separate alarms, sound level typically better than 85 dBA at 30 cm
- integrated dose
- dose rate
- dose overfl ow
- dose rate over fl ow at 3 Sv/h or 300 rem/h
- low battery 1and 2
- defect
Alarm thresholds*:
•
seven preset values each for integrated dose and dose rate, manually
selectable by push-button
Push-button functions*:
•
- front panel push-button has the following selectable functions:
- toggle between dose and dose rate display
- switch ON/OFF
- chirp ON/OFF
- reset integrated dose
- change alarm thresholds
- activate battery test
*Note: the active alarm tresholds and confi guration of push button functions
can be changed by using ADR-1 Reader Head in combination with RADOS PC
Software.
Mechanical characteristics
Dimensions: 78 x 67 x 22 mm
•
Weight: 80 g including battery
•
Envirionmental Characterstics
Temperature range:
•
-20 oC to +50 oC operational, humidity up to 90% RH, non condensed
Electrical characteristics
Power supply:
•
one triple A alkaline cell, life typically 1800 h in background fi eld (dose mode)
Reader communication:
•
by infrared through bottom part; by using ADR-1 Reader Head in
•
combination with RADOS PC software