Health physics division, Passive measurement components ** selectable units, Alarm levels typical one year lifetime with – Mirion Technologies SOR-T User Manual
Page 2: Standard battery user selectable display modes, Backlighted display (option), Periodic exhaustive self-testing, Real time teledosimetry transmission, Flash gamma dose measurement**: 5 cgy to 10 gy, Flash neutron dose management, 1μgy to 10 gy gamma dose rate measurement range

Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technolgies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Health Physics
Division
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
SOR/T - SOR/R
Active Dosimetry - Dosimeters
www.mirion.com
144258EN-B
FUNCTIONAL CHARACTERISTICS
Redundant architecture with
●
passive measurement components **
Selectable units:
●
cGy; cGy/h; mSv; mSv/h; mrem;
mrem/h
4 confi gurable dose and dose rate
●
alarm levels
Typical one year lifetime with
●
standard battery
User selectable display modes
●
Backlighted display (option)
●
Periodic exhaustive self-testing
●
including the detector
Historical record of measurements
●
and events (750 steps; 10 s;
1 min ;10 min; 1 h; 24 h)
Data storage in EEPROM (qualifi ed
●
> 10 years without battery)
Battery low (16 h) pre-alarm and
●
alarm if the battery is removed
Neck lanyard or clip
●
Real time teledosimetry transmission
●
(up to 1000 m - 3281 ft range) for SOR/R
Training mode included***
●
PHYSICAL CHARATERISTICS
Hp(10) dose equivalent measurements
●
Flash gamma dose measurement**: 5 cGy to 10 Gy
●
Flash neutron dose management**
●
Relative error of fl ash measurement**: ± 30 % over
●
measurement range
Ambient gamma dose measurement range:
●
1μGy to 10 Gy
Gamma dose rate measurement range:
●
from 0.1 μGy/h to 10 Gy/h
Gamma dose rate display:
●
from 1 or 10 μGy/h to 10 Gy/h
Saturation indication (above 10 Gy/h)
●
Relative error of ambient measurement:
●
<± 20 % over the dose measurement range
○
Energy response:
●
<± 20 % in the range 60 keV to 2 MeV
○
<± 50 % in the range 2 MeV to 6 MeV
○
Accredited factory calibration to IEC 17025
●
Accuracy <± 10 % (
●
137
Cs, ~ 25 mSv/h including ± 5 %
of extended uncertainty K=2)
MECHANICAL CHARACTERISTICS
Dimensions: 80.4 x 48 x 9 mm (fl at housing)
●
(3.16 x 1.85 x 0.35 in)
Weight: 55 g (1.94 oz)
●
ENVIRONMENTAL CHARACTERISTICS
-20° to + 50°C (-4°F + 122°F) (normal operating range,
●
standard battery 3V LiMnO
2
CR2450)
-40° to + 50°C (-40°F + 122°F) (option with battery
●
module 3.6V LiSoCl
2
)
TREE protection (SOR/R and SOR/T)
●
Resistant to EMP, EMC, radars
●
Resistant to water immersion (IP67: 1 m / 39.3 in) ,
●
drops, shocks,vibrations, low pressure,
Initial conditions, NBC environmental conditions
○
Complies with the following standards:
●
Meets MIL-STD-810 and MIL-STD-461 requirements
○
Qualifi ed by most of the NATO military laboratories
○
Complies with IEC 1283, ANSI 42-20 and NATO D104
○
NATO supplier n° F8929
Development status: Series production
* LLR : Low level Radiation
** special characteristics of the SOR/T