beautypg.com

Health physics division, 20 characters 4 indicator lights, Function indicator 2 access control lights – Mirion Technologies LDM 2000 User Manual

Page 2: Alphanumeric keyboard for data entry, Buzzer for audible alarms, Pass-by data exchange with range adjustment, Typical consumption 25 va, Connections, 3 isolated digital inputs, 3 relay outputs

background image

Mirion Technologies (MGPI) Inc

5000 Highlands Parkway

Suite 150

Smyrna Georgia 30082

USA

T +1.770.432.2744

F +1.770.432.9179

Mirion Technologies (MGPI) SA

BP 1

F-13113 Lamanon

France

T +33 (0) 4 90 59 59 59

F +33 (0) 4 90 59 55 18

Mirion Technologies (RADOS) Oy

P.O. Box 506

FIN-20101 Turku

Finland

T +358 2 468 4600

F +358 2 468 4601

Mirion Technolgies (RADOS) GmbH

Ruhrstrasse 49

DE-22761 Hamburg

Germany

T +49 (0) 40 851 93-0

F +49 (0)40 851 93 256

Health Physics
Division

Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.

LDM 2000

Active Dosimetry - Readers

www.mirion.com

144502EN-C

FUNCTIONAL CHARACTERISTICS

Back-light alphanumeric display with 4 lines of

20 characters

4 indicator lights:

2 lights for viewing dosimeter exchanges and monitor

function indicator

2 access control lights

Alphanumeric keyboard for data entry

Buzzer for audible alarms

Pass-by data exchange with range adjustment

Memory of more than 2000 entries/exits

in autonomous emergency mode

ELECTRICAL CHARACTERISTICS

Power supply:

85 to 265 V AC 50 to 60 Hz

typical consumption 25 VA

Connections:

3 isolated digital inputs

3 relay outputs

1 «centralizer» RS 232 or RS 485 serial interface

1 «auxiliary» RS 232 serial interface

1 external antenna connection

MECHANICAL CHARACTERISTICS

Dimensions:

Height: 235 mm (9.2 in)

Width: 297 mm (11.7 in)

Depth: 97 mm (3.8 in)

Weight: 3.67 kg (8 lbs)

ENVIRONMENTAL CHARACTERISTICS

Operating temperature: 0°C to +50°C ( 32°F to 122°F )

or -20°C to +60°C (-4°F to 140°F) option

Storage temperature: -25°C to +60°C (-13°F to 140°F)

EMC: complies with and exceeds CE standards

LINK WITH DMC 2000 DOSIMETERS

Link in pass-by mode by magnetic coupling 125 kHz

Range up to 1.2 m (3.93 ft) for in-motion reading

(2.4 m / 7.87 ft with external antenna added)

OPTIONS AND ACCESSORIES

Without internal antenna

Additional external antenna

Connector band with HE 308 socket, access control

report and lights

Ethernet module

Sleeve for DMC 2000S, X, XB and GN

Backup power supply, over 1 hour battery life

Pass-by data exchange

offers unequaled operational fl exibility:

sub-area tracking plus real-time worker

location, without imposing any restrictions

on the dosimeter wearer.