teCHNICaL SPeCIFICatIONS:

Detector

• GM Tube ZP-1301 (or equiv) High Range
• GM Tube ZP-1201 (or equiv) Low Range
• Optional GM Tube ZP-1300 non-energy compensated
• Optional CsI (2 x 2) detector

Measurement Range

• 5 u/hr to 1000 R/hr (GM); 1 u/hr to 10 mr/hr (CsI)

• Automatic switching between GM detectors at 800 mr/hr and 600 mr/hr

accuracy

+ 10% of reading, within the measurement range

energy Response

+ 20% at 70 keV to 1.1 MeV

Sensitivity (Cs137)

• 17 cps/mr/hr (Low Range):
• 0.3cps/mr/hr (High Range)

Display

• 6 Segment LCD (non-backlit) - units mR/h optional uSv/h

audible alarms
Indicator Lamps
alarm acknowledgement Button

• Two side mounted Piezos speakers - alarm sound level >95 dB
• Green and Red LED status indicators
• One Push-switch

Power

• External power supply and battery backup: External power supply: Input 120-250 VAC,
• Output 6-15 Vdc with locking connector
• Battery Back-up: Three (3) 1.2v NiMH 2100mA rechargeable
• Battery operating life: up to ~ 8 hours continuous

temperature Range

• Operation: 15

o

F to 122

o

F

• Storage: -5

o

F to 140

o

F

Humidity

• 10% to 95% RH (non-condensing)

Dimensions

• 4.8” W x 8.4” L x 4.2” H (212 mm x 123 mm x 107 mm)

Weight

• 2.75 lbs. (1247 gm)

www.mirion-hp.com