Emergency Kit for radiation protection applications

Portable Survey Meters

20996039_EMERGENCYKIT_EN_B

TECHNICAL SPECIFICATIONS:

RDS-30 Radiation Survey Meter

Radiation detected: gamma and X-ray from 48 keV to 1.3 MeV

Dose rate measurement range: from 0.01 µSv/h to 100 mSv/h or from 1 µrem/h to 10 rem/h

Dose measurement range: from 0.01 µSv to 1 Sv or from 1 µrem to 100 rem

Dose rate linearity: ± 10 % ±1 digit within the range of 0.1 µSv/h to 100 mSv/h or

10 µrem/h to 10 rem/h
Energy response: ± 30 % over the range of 48 keV - 1.3 MeV

Angular response: ± 25 % within ± 45 % from the calibration direction at 48 keV

RDS-80 Surface Contamination Meter

Radiation detected: alpha >2 MeV, beta

Emax

>100 keV, gamma and x-rays from 5 keV to 1.3 MeV

Measurement range: surface contamination 1 to 100 000 cps or 0.01 to 100 000 Bq cm

2

Alarm levels: freely adjustable alarm levels for contamination level

Cps linearity: ±15% ±1 digit within the range of 10 to 100 000 cps, the Bq/cm2 display is calcu-

lated from cps values by multiplying with Isotope coeffi cient

RAD-60 personal Alarm Dosimeter

Radiation detected: gamma and X-rays

Detectors: energy compensated Si-Diode

Dose rate measurement range: 5 µSv/h - 3 Sv/h or 0,5 mrem/h - 300 rem/h

Dose measurement range: 1 µSv - 9.99 Sv or 0.1 mrem - 999 rem

Energy response: Hp(10), 60 keV - 3 MeV, better than ±25%, up to 6 MeV, better than ±35

Alarm thresholds: seven preset values each for integrated dose and dose rate, manually select-

able by push-button

DMC Electronic Dosimeters

Alarming dose rate meter

Dose measurement range: 1µSv - 10 Sv

Dose rate measurement range: 0.1µSv/ - 10 Sv/h

HP(10) 50 keV - 6 Mev

SOR/R and SOR/T

Ambient and Residual X and Gamma: same as DMC2000S

Hands-free with the XOM reader even through NBC clothing

Waterproof

Shock proof

EMP and TREE resistant

-20°C or –40°C with Li-SOCL2 battery

Flash Gamma and Neutron (SOR/T version only