Meter specifications – Max Machinery G240 Gear Flow Meter User Manual
Page 6

Max Machinery, Inc. G Series User Manual © Copyright 2013
Rev. 001Q4
Meter Specifications
Model
G004 G015 G045 G105 G240
1
Maximum flow rate
Liters/min:
4
15
45
105
240
Gal/min:
1
4
11.9
28
64
Maximum pressure (psi)
|-----------------------425 bar (6000 psi)-----------------------|
see below
2
Maximum temperature
--------------------- 2 part: 225°C (435°F) --------------------
3
Recommended filtration
10 micron
15 micron
20 micron
20 micron
30 micron
Displacement (cc/rev)
1.8
4.2
13.5
38
133
Weight (kg)
1.2
1.8
3.7
7.7
21
Typical k-factor (pulses/cc)
500
200 70
25
7
NPT Port size
1/8”
3/8”
1/2”
3/4”
1” to 280 bar (4000 psi)
SAE Port Size
#4
#6
#8
#10
#16 to 425 bar (6000psi)
1
For viscosities of 100 cps or more, derate per pressure drop curves for higher viscosities.
2
Standard transmitter capable to 90°C (195°F)
3
Some materials may have different filter requirements, consult factory.