Model g004 flow meter, 1/8" npt, Not to scale 2.26 – Max Machinery G240 Gear Flow Meter User Manual
Page 15: Typical pressure drop

Max Machinery, Inc. G Series User Manual © Copyright 2013
Rev. 001Q4
1/8" NPT
1/8" NPT
EX-PROOF HOUSING
TOP VIEW
not to scale
2.26”
(57mm)
2.26”
(57mm)
0.65”
(17mm)
1.93”
(49mm)
1/8” NPT
3.70”
(94mm)
1.75”
(45mm)
1.75”
(45mm)
1/2”
NPT
4.09”
(104mm)
2.26”
(57mm)
1/8” NPT
mounting holes
1/4” - 20NC
(4) places
2.6”
(66mm)
2.75”
(70mm)
MODEL G004 WITH INDUSTRIAL
HOUSING TRANSMITTER
MODEL G004 WITH EX-PROOF
HOUSING TRANSMITTER
BOTTOM VIEW
1.5”
(38mm)
Flow Rate (liters/min)
Pr
es
sur
e Dr
op (p
si)
120
140
20
40
60
100
TYPICAL PRESSURE DROP
Intermittent Duty Area
Expected Failure Area
Continuous Duty Area
80
3
0 cP
100 cP
1000
cP
10,
00
0 c
P
—
8 bar
—
6 bar
—
4 bar
— —
2 bar
2 cP
0.001
0.01
0.1
1
10
Model G004 Flow Meter