TIMING RETARD WIRES
Stage-1 ORANGE wire
Stage-2 YELLOW wire
Stage-3 BROWN wire

Each retard circuit activates when connected to a
switched 12-volt source and switched “ON.” Many
types of switches can be used such as a dash
mounted toggle switch, a push button switch on the
steering wheel (such as a nitrous system switch), a
switch on the transmission shifter or an RPM activated
switch. It is not necessary to switch “OFF” a previous
stage for a succeeding stage to override the previous
stage. When all 12-volt sources for the retard circuits
are switched “OFF,” the retard circuits revert to normal
ignition timing.

to the ignition control, transfer the magnetic pickup
wires to the magnetic pickup connector (small
PURPLE/MAG+ and small GREEN/MAG– wires) on the
control box.

If you are using a magnetic pickup, such as a crank
trigger, and the magnetic pickup wires are connected
to another timing accessory, the magnetic pickup
wires shall remain connected to that timing accessory.
The magnetic pickup connector on the control box will
not be used. Install the female receptacle terminal on
the trigger output wire from the timing accessory and
connect it to the GREEN (trigger input) wire with the
male receptacle terminal.

If you are using an electronic ignition distributor, install
the female receptacle terminal on the trigger output
wire from the ignition module and connect it to the
GREEN (trigger input) wire with the male receptacle
terminal.

TRIGGER OUTPUT
Connect the WHITE wire with the female receptacle
terminal to the point or electronic ignition amplifier

www.mrgasket.com